beiscsi does not need the iscsi scsi cmd processing. It does not
even get this info on the completion path. This adds a function
to just update the sequencing numbers and complete a task.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: Jayamohan Kallickal <jayamohank@serverengines.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Patch to add debugging stuff for rdac device handler.
- Added a bit mask "module parameter" rdac_logging with 2 bits for each type
of logging.
- currently defined only two types of logging(failover and sense logging). Can
be enhanced later if required.
- By default only failover logging is enabled which is equivalent of current
logging.
Signed-off-by: Babu Moger <babu.moger@lsi.com>
Reviewed-by: Vijay Chauhan <vijay.chauhan@lsi.com>
Reviewed-by: Bob Stankey <Robert.stankey@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Adding the code to read the debug information during initialization. This
patch collects the information about storage and controllers during
rdac_activate.
Signed-off-by: Babu Moger <babu.moger@lsi.com>
Reviewed-by: Vijay Chauhan <vijay.chauhan@lsi.com>
Reviewed-by: Bob Stankey <Robert.stankey@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Moving the initialization code from rdac_activate to rdac_bus_attach which is
more efficient. We don't have to collect all the information during every
activate.
Signed-off-by: Babu Moger <babu.moger@lsi.com>
Reviewed-by: Vijay Chauhan <vijay.chauhan@lsi.com>
Reviewed-by: Bob Stankey <Robert.stankey@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When the allocation fails in sg_build_indirect(), an oops happens in
the error path. It's caused by an obvious typo.
Signed-off-by: Michal Schmidt <mschmidt@redhat.com>
Reported-by: Bob Tracy <rct@gherkin.frus.com>
Acked-by: Douglas Gilbert <dgilbert@interlog.com>
Cc: Stable Tree <stable@kernel.org>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Normally In HBA reset path MPT driver will flush existing work in current work
queue (mpt/0) . This is just a dummy activity for MPT driver point of
view, since HBA reset will turn off Work queue events.
It means we will simply returns from work queue without doing anything.
But for the case where Work is already done (half the way), we have to have
that work to be done.
Considering above condition we stuck forever since Deadlock in scsi midlayer
and MPT driver. sd_sync_cache() will wait forever since HBA is not in
Running state, and it will never come into Running state since
sd_sync_cache() is called from HBA reset context.
Now new code will not wait for half cooked work to be finished
before returning from HBA reset.
Once we are out of HBA reset, EH thread will change host state to running from
recovery and work waiting for running state of HBA will be finished.
New code is turning ON firmware event from another special work called
Rescan toplogy.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Driver is modified to return DID_NO_CONNECT for all pending I/O
requests for bus type SAS, if it founds the target is removed at
the firmware level.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch is solving problem for PAE kernel DMA operation.
On PAE system dma_addr and unsigned long will have different
values.
Now dma_addr is not type casted using unsigned long.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
On Big endian system kernel will crash due to address translation
is not handle properly.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Check for phyinfo->phy before calling sas_port_delete_phy.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Original code would inadvertently skip the deferred
fc_remote_port_delete() call for rports hanging off any vport.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Original code would break-out of loop after only one iteration.
Signed-off-by: Lalit Chandivade <lalit.chandivade@qlogic.com>
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In fabric-login based on iop BIT_8 firmware notifies presence of
a FCP2 device and not necessarily a TAPE device. So instead of
setting FCF_TAPE_PRESENT flag there we set it using
scsi_device->type after mid-layer scan recognises "type" of the
device.
It also adds a new flag FCF_FCP2_DEVICE for any future use.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This fixes one cause of an occational problem when unloading
libfc where the exchange manager pool doesn't have all items freed.
The existing WARN_ON(mp->total_exches <= 0) isn't hit.
However, note that total_exches is decremented when the
exchange is completed, and it can be held with a refcnt
for a while after that.
I'm not sure what the offending exchange is, but I suspect
it is an incoming request, because outgoing state machines
should be all stopped at this point.
Note that although receive is stopped before the exchange
manager is freed, there could still be active threads
handling received frames.
This patch flushes the queues by allocating a new skb
and sending it through, and have the thread handle
this new skb specially. This is similar to the way the work
queues are flushed now by putting work items in them and waiting
until they make it through the queue.
An skb->destructor function is used to inform us of
the completion of the flush, and the fr_dev() is left
NULL to indicate to fcoe_percpu_receive_thread() that
the skb should be just freed. There's already a check
for the lp being NULL which prints a message.
We skip printing the message if the destructor is for flushing.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
I saw an lport debug message from the exchange manager saying:
"lport 70500: Received response for out of range oxid:ffff"
A trace showed this was a BA_RJT sent due to an incoming ABTS
which arrived on an unknown exchange. So, the sender of the
BA_RJT was in error, but in this case, both the initiator and
responder were the same machine.
The OX_ID and RX_ID should not have been reversed in this case.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When an RSCN indicates changes to individual remote ports,
don't blindly log them out and then back in. Instead, determine
whether they're still in the directory, by doing GPN_ID.
If that is successful, call login, which will send ADISC and reverify,
otherwise, call logoff. Perhaps we should just delete the rport,
not send LOGO, but it seems safer.
Also, fix a possible issue where if a mix of records in the RSCN
cause us to queue disc_ports for disc_single and then we decide
to do full rediscovery, we leak memory for those disc_ports queued.
So, go through the list of disc_ports even if doing full discovery.
Free the disc_ports in any case. If any of the disc_single() calls
return error, do a full discovery.
The ability to fill in GPN_ID requests was added to fc_ct_fill().
For this, it needs the FC_ID to be passed in as an arg.
The did parameter for fc_elsct_send() is used for that, since the
actual D_DID will always be 0xfffffc for all CT requests so far.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The local port facility has been replying to ADISC requests without
looking to see if the remote port is logged in. This is incorrect.
An ADISC request requires PLOGI first. It should be rejected if
the sending remote port is not logged in.
This is like other incoming requests that require login, all of
which should be handled in the remote port module.
Move the ADISC request handling from fc_lport.c to fc_rport.c.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When rport_login is called on an rport that is already thought
to be logged in, use ADISC. If that fails, redo PLOGI.
This is less disruptive after fabric changes that don't affect
the state of the target.
Implement the sending of ADISC via fc_els_fill.
Add ADISC state to the rport state machine. This is entered from READY
and returns to READY after successful completion. If it fails, the rport
is either logged off and deleted or re-does PLOGI.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
fc_rport_logo_resp() had a call to fc_rport_enter_rtv() if the
LOGO was accepted. This must've been a copy/paste mistake, but
it didn't matter since we don't stay in the LOGO state long enough
to hit this code.
Change fc_rport_logo_resp() to just enter the delete state
no matter what.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
After a quick link flap, a target was seen to send us a LOGO.
Apparently, it saw an RSCN reporting that we had dropped out of the
fabric after we had logged back into it.
This is likely in larger fabrics (more than 2 FC switches) after
a quick link flap at the initiator. Each link transition causes
an port-specific RSCN to the target. After the link comes back up,
the initiator successfully discovers and does a PLOGI to the target
before the target sees the first RSCN reporting the initiator is gone,
and it sends a LOGO. The target may see a subsequent RSCN saying the
port is back, but probably wouldn't send a PLOGI and leaves it
up to the initiator to re-login.
An RSCN can be delayed by the switches due to software layers but a
PLOGI is forwarded in hardware causing the PLOGI to beat the RSCN.
If a remote port is in the discovered set and sends a LOGO, re-login to it.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When receiving an ELS request, if the request isn't recognized,
the unsupported operation error should be given even if the port
is not found or not logged in.
Also, the LOGO request shouldn't give the login-required explanation.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
libfc receives PLOGIs from switches which are trying to discover what
kind of devices are present, and from other initiators to find out
if we're a target.
As an initiator, some argue we don't need to handle incoming PLOGI
requests, and we currently reject them from unknown remote ports,
but accept them is we're in the middle of a PLOGI to the remote port.
For eventual target implementations, we want to handle them always.
For incoming PLOGI, don't fail if the rport_priv doesn't exist.
Just create it and go become READY without going through PRLI. If
PRLI occurs, then our roles will be set and we'll become READY again.
Also, allow incoming PRLI in RTV state.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Improve lport and rport debug messages to indicate whether
the response is LS_ACC, LS_RJT, closed, or timeout.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The rport_lookup function must be called while holding the disc_mutex.
Otherwise, the rdata could be deleted just after that by another thread.
All callers now check the state after grabbing the rdata rp_mutex.
Even though rport_lookup skips ports in DELETE state, it does that
without holding the rdata rp_mutex, so that the state may change.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This moves the remote port lookup for incoming ELS requests into
fc_rport.c, in preparation for handing PLOGI and LOGO from
unknown rports.
This changes the arg to rport_recv_req from an rdata to an lport.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Don't trust previous roles, reset them when we receive a PRLI.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Currently these values are initialized by the callers. This was exposed
by a later patch that adds PLOGI request support. The patch failed to
initialize the new remote port's roles and it caused problems. This patch
has the rport_create routine initialize the identifiers and then the
callers can override them with real values.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
It's possible to "restart" discovery before it was started if
an RSCN is received early enough. We were jumping to 0
due to the disc_callback function pointer not getting set.
Don't restart discovery if disc_callback is NULL.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The discovery code had a special-case for the point-to-point mode,
which used a bunch of code that wasn't really needed.
Now that rport_create adds the rport to the discovery list,
completely skip discovery for the point-to-point case.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In fc_disc_gpn_ft_parse(), after fc_disc_done() is called, the
disc state is changed by setting buf_len = 0. This is wrong
since the discovery may have restarted. Instead, return
after calling fc_disc_done.
Also, return an error on memory allocation failure.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Currently fc_disc_timeout() restarts discovery only if it is not pending.
When the timer is scheduled, the discovery is left pending, so the
timeout never restarts it.
Fix by not checking for pending in the timeout handler.
If discovery is stopped and restarted in the meantime, the timeout will
be canceled.
Also, when a new discovery is started, the retry count wasn't cleared.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
On some switches, an empty zone causes GPN_FT to be rejected
with reason 9 (unable) explanation 7 (FC-4 types not registered),
which causes discovery to be retried endlessly. Treat this as
just an empty response and consider discovery complete.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Abhijeet Joglekar wrote: "In gpn_ft_resp, if the payload is short,
or unexpected response or out of sequence frame, then we just
return and do nothing. We should either enter fc_disc_done()
with DISC_EV_FAIL which will then restart any queued discovery
requests or call lport module which will reset local port,
or we should call fc_disc_error() so that the gpn_ft is retried.
The situation as is causes discovery to remain pending and never
get restarted, in these rare cases. We saw this due to a coding
bug in fc_disc before. The only ways it could happen would be
bugs, packet corruption or an FC fabric problem.
Change it to fail discovery. The local port will restart
discovery, although it probably should just give up until
the next link flap.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Code cleanup for fc_disc_gpn_ft_resp().
Some of the fc_disc.c code was poorly formatted. For example, some lines
in fc_disc.c were unnecessarily truncated and the buf variable could
be eliminated.
Also moved the increment of seq_count into fc_disc_gpn_ft_parse(), to
avoid doing it separately before each call.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When an RSCN is received during fabric discovery, it restarts.
After the restart, disc->seq_count was incremented, so when
the first frame was received, it was considered "out of sequence".
That left the state disc->active, preventing further discoveries.
Change to advance the sequence count before parsing, so that it
won't be changed after a potential restart.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When receiving an RSCN, do not log off all rports. This is
extremely disruptive. If, after the GPN_FT response, some
rports haven't been listed, delete them.
Add field disc_id to structs fc_rport_priv and fc_disc.
disc_id is an arbitrary serial number used to identify the
rports found by the latest discovery. This eliminates the need
to go through the rport list when restarting discovery.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Move the libfc remote port lookup function into fc_rport.c.
This seems like the best place for it.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Since the rport list maintenance is now done in the rport module,
the callback (and ops) are usually not necessary.
Allow rdata->ops to be left NULL if nothing needs
to be done in an event callback.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For future discovery patches, change rport_create to return a previously
created rport_priv that has the FC_ID as long as it isn't in deleted state.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The list of remote ports (struct fc_rport_priv) has been
maintained by the discovery module. In preparation for having
lport->tt.rport_create() do a lookup first, maintain the
rports list in the rport module. It will still be protected
by the disc_mutex.
The DNS rport is an exception for until after further patches.
For now, do not add it to the list.
The point-to-point rport will be in the discovery list.
So at shutdown, it doesn't need to be separately logged out.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The lport rport callback can only be called for the dNS rport,
since its the only rport who's ops point to that function.
Remove unnecessary checking and debug messages.
Put the locking outside the switch statement as a simplification.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Don't print large negative decimal numbers for frame pointers in
the debug messages from fc_rport_error(). Just print 0 if its a
frame pointer, and print the error numbers as positive.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Delete unused disc->delay element.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
There was no need to have the discovery status stored in struct fc_disc.
Change fc_disc_done() to take the discovery status as an argument
and just pass it on to the discovery callback.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>