[SCSI] libfc: move remote port lookup for ELS requests into fc_rport.c.
This moves the remote port lookup for incoming ELS requests into fc_rport.c, in preparation for handing PLOGI and LOGO from unknown rports. This changes the arg to rport_recv_req from an rdata to an lport. Signed-off-by: Joe Eykholt <jeykholt@cisco.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This commit is contained in:
parent
6bd054cbf3
commit
131203a1ef
3 changed files with 44 additions and 66 deletions
|
@ -812,10 +812,6 @@ static void fc_lport_recv_req(struct fc_lport *lport, struct fc_seq *sp,
|
|||
{
|
||||
struct fc_frame_header *fh = fc_frame_header_get(fp);
|
||||
void (*recv) (struct fc_seq *, struct fc_frame *, struct fc_lport *);
|
||||
struct fc_rport_priv *rdata;
|
||||
u32 s_id;
|
||||
u32 d_id;
|
||||
struct fc_seq_els_data rjt_data;
|
||||
|
||||
mutex_lock(&lport->lp_mutex);
|
||||
|
||||
|
@ -831,7 +827,7 @@ static void fc_lport_recv_req(struct fc_lport *lport, struct fc_seq *sp,
|
|||
/*
|
||||
* Check opcode.
|
||||
*/
|
||||
recv = NULL;
|
||||
recv = lport->tt.rport_recv_req;
|
||||
switch (fc_frame_payload_op(fp)) {
|
||||
case ELS_FLOGI:
|
||||
recv = fc_lport_recv_flogi_req;
|
||||
|
@ -858,29 +854,7 @@ static void fc_lport_recv_req(struct fc_lport *lport, struct fc_seq *sp,
|
|||
break;
|
||||
}
|
||||
|
||||
if (recv)
|
||||
recv(sp, fp, lport);
|
||||
else {
|
||||
/*
|
||||
* Find session.
|
||||
* If this is a new incoming PLOGI, we won't find it.
|
||||
*/
|
||||
s_id = ntoh24(fh->fh_s_id);
|
||||
d_id = ntoh24(fh->fh_d_id);
|
||||
|
||||
rdata = lport->tt.rport_lookup(lport, s_id);
|
||||
if (rdata)
|
||||
lport->tt.rport_recv_req(sp, fp, rdata);
|
||||
else {
|
||||
rjt_data.fp = NULL;
|
||||
rjt_data.reason = ELS_RJT_UNAB;
|
||||
rjt_data.explan = ELS_EXPL_NONE;
|
||||
lport->tt.seq_els_rsp_send(sp,
|
||||
ELS_LS_RJT,
|
||||
&rjt_data);
|
||||
fc_frame_free(fp);
|
||||
}
|
||||
}
|
||||
recv(sp, fp, lport);
|
||||
} else {
|
||||
FC_LPORT_DBG(lport, "dropping invalid frame (eof %x)\n",
|
||||
fr_eof(fp));
|
||||
|
|
|
@ -912,57 +912,61 @@ static void fc_rport_enter_logo(struct fc_rport_priv *rdata)
|
|||
* fc_rport_recv_req() - Receive a request from a rport
|
||||
* @sp: current sequence in the PLOGI exchange
|
||||
* @fp: response frame
|
||||
* @rdata_arg: private remote port data
|
||||
* @lport: Fibre Channel local port
|
||||
*
|
||||
* Locking Note: Called without the rport lock held. This
|
||||
* function will hold the rport lock, call an _enter_*
|
||||
* function and then unlock the rport.
|
||||
* Locking Note: Called with the lport lock held.
|
||||
*/
|
||||
void fc_rport_recv_req(struct fc_seq *sp, struct fc_frame *fp,
|
||||
struct fc_rport_priv *rdata)
|
||||
struct fc_lport *lport)
|
||||
{
|
||||
struct fc_lport *lport = rdata->local_port;
|
||||
|
||||
struct fc_rport_priv *rdata;
|
||||
struct fc_frame_header *fh;
|
||||
struct fc_seq_els_data els_data;
|
||||
u32 s_id;
|
||||
u8 op;
|
||||
|
||||
mutex_lock(&rdata->rp_mutex);
|
||||
|
||||
els_data.fp = NULL;
|
||||
els_data.explan = ELS_EXPL_NONE;
|
||||
els_data.reason = ELS_RJT_NONE;
|
||||
|
||||
fh = fc_frame_header_get(fp);
|
||||
s_id = ntoh24(fh->fh_s_id);
|
||||
|
||||
if (fh->fh_r_ctl == FC_RCTL_ELS_REQ && fh->fh_type == FC_TYPE_ELS) {
|
||||
op = fc_frame_payload_op(fp);
|
||||
switch (op) {
|
||||
case ELS_PLOGI:
|
||||
fc_rport_recv_plogi_req(rdata, sp, fp);
|
||||
break;
|
||||
case ELS_PRLI:
|
||||
fc_rport_recv_prli_req(rdata, sp, fp);
|
||||
break;
|
||||
case ELS_PRLO:
|
||||
fc_rport_recv_prlo_req(rdata, sp, fp);
|
||||
break;
|
||||
case ELS_LOGO:
|
||||
fc_rport_recv_logo_req(rdata, sp, fp);
|
||||
break;
|
||||
case ELS_RRQ:
|
||||
els_data.fp = fp;
|
||||
lport->tt.seq_els_rsp_send(sp, ELS_RRQ, &els_data);
|
||||
break;
|
||||
case ELS_REC:
|
||||
els_data.fp = fp;
|
||||
lport->tt.seq_els_rsp_send(sp, ELS_REC, &els_data);
|
||||
break;
|
||||
default:
|
||||
els_data.reason = ELS_RJT_UNSUP;
|
||||
lport->tt.seq_els_rsp_send(sp, ELS_LS_RJT, &els_data);
|
||||
break;
|
||||
}
|
||||
rdata = lport->tt.rport_lookup(lport, s_id);
|
||||
if (!rdata) {
|
||||
els_data.reason = ELS_RJT_UNAB;
|
||||
lport->tt.seq_els_rsp_send(sp, ELS_LS_RJT, &els_data);
|
||||
fc_frame_free(fp);
|
||||
return;
|
||||
}
|
||||
mutex_lock(&rdata->rp_mutex);
|
||||
|
||||
op = fc_frame_payload_op(fp);
|
||||
switch (op) {
|
||||
case ELS_PLOGI:
|
||||
fc_rport_recv_plogi_req(rdata, sp, fp);
|
||||
break;
|
||||
case ELS_PRLI:
|
||||
fc_rport_recv_prli_req(rdata, sp, fp);
|
||||
break;
|
||||
case ELS_PRLO:
|
||||
fc_rport_recv_prlo_req(rdata, sp, fp);
|
||||
break;
|
||||
case ELS_LOGO:
|
||||
fc_rport_recv_logo_req(rdata, sp, fp);
|
||||
break;
|
||||
case ELS_RRQ:
|
||||
els_data.fp = fp;
|
||||
lport->tt.seq_els_rsp_send(sp, ELS_RRQ, &els_data);
|
||||
break;
|
||||
case ELS_REC:
|
||||
els_data.fp = fp;
|
||||
lport->tt.seq_els_rsp_send(sp, ELS_REC, &els_data);
|
||||
break;
|
||||
default:
|
||||
els_data.reason = ELS_RJT_UNSUP;
|
||||
lport->tt.seq_els_rsp_send(sp, ELS_LS_RJT, &els_data);
|
||||
break;
|
||||
}
|
||||
|
||||
mutex_unlock(&rdata->rp_mutex);
|
||||
|
|
|
@ -598,7 +598,7 @@ struct libfc_function_template {
|
|||
* STATUS: OPTIONAL
|
||||
*/
|
||||
void (*rport_recv_req)(struct fc_seq *, struct fc_frame *,
|
||||
struct fc_rport_priv *);
|
||||
struct fc_lport *);
|
||||
|
||||
/*
|
||||
* lookup an rport by it's port ID.
|
||||
|
|
Loading…
Reference in a new issue