Kernel driver ltc4245
=====================
Supported chips:
* Linear Technology LTC4245
Prefix: 'ltc4245'
Addresses scanned: 0x20-0x3f
Datasheet:
http://www.linear.com/pc/downloadDocument.do?navId=H0,C1,C1003,C1006,C1140,P19392,D13517
Author: Ira W. Snyder <iws@ovro.caltech.edu>
Description
-----------
The LTC4245 controller allows a board to be safely inserted and removed
from a live backplane in multiple supply systems such as CompactPCI and
PCI Express.
Usage Notes
-----------
This driver does not probe for LTC4245 devices, due to the fact that some
of the possible addresses are unfriendly to probing. You will need to use
the "force" parameter to tell the driver where to find the device.
Example: the following will load the driver for an LTC4245 at address 0x23
on I2C bus #1:
$ modprobe ltc4245 force=1,0x23
Sysfs entries
-------------
The LTC4245 has built-in limits for over and under current warnings. This
makes it very likely that the reference circuit will be used.
This driver uses the values in the datasheet to change the register values
into the values specified in the sysfs-interface document. The current readings
rely on the sense resistors listed in Table 2: "Sense Resistor Values".
in1_input 12v input voltage (mV)
in2_input 5v input voltage (mV)
in3_input 3v input voltage (mV)
in4_input Vee (-12v) input voltage (mV)
in1_min_alarm 12v input undervoltage alarm
in2_min_alarm 5v input undervoltage alarm
in3_min_alarm 3v input undervoltage alarm
in4_min_alarm Vee (-12v) input undervoltage alarm
curr1_input 12v current (mA)
curr2_input 5v current (mA)
curr3_input 3v current (mA)
curr4_input Vee (-12v) current (mA)
curr1_max_alarm 12v overcurrent alarm
curr2_max_alarm 5v overcurrent alarm
curr3_max_alarm 3v overcurrent alarm
curr4_max_alarm Vee (-12v) overcurrent alarm
in5_input 12v output voltage (mV)
in6_input 5v output voltage (mV)
in7_input 3v output voltage (mV)
in8_input Vee (-12v) output voltage (mV)
in5_min_alarm 12v output undervoltage alarm
in6_min_alarm 5v output undervoltage alarm
in7_min_alarm 3v output undervoltage alarm
in8_min_alarm Vee (-12v) output undervoltage alarm
in9_input GPIO #1 voltage data
in10_input GPIO #2 voltage data
in11_input GPIO #3 voltage data
power1_input 12v power usage (mW)
power2_input 5v power usage (mW)
power3_input 3v power usage (mW)
power4_input Vee (-12v) power usage (mW)