kernel-fxtec-pro1x/net/tipc/Kconfig
Allan Stephens f831c963b5 tipc: Eliminate configuration for maximum number of cluster nodes
Gets rid of the need for users to specify the maximum number of
cluster nodes supported by TIPC. TIPC now automatically provides
support for all 4K nodes allowed by its addressing scheme.

Note: This change sets TIPC's memory usage to the amount used by
a maximum size node table with 4K entries.  An upcoming patch that
converts the node table from a linear array to a hash table will
compact the node table to a more efficient design, but for clarity
it is nice to have all the Kconfig infrastruture go away separately.

Signed-off-by: Allan Stephens <Allan.Stephens@windriver.com>
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
2011-03-13 16:35:17 -04:00

69 lines
2.1 KiB
Text

#
# TIPC configuration
#
menuconfig TIPC
tristate "The TIPC Protocol (EXPERIMENTAL)"
depends on INET && EXPERIMENTAL
---help---
The Transparent Inter Process Communication (TIPC) protocol is
specially designed for intra cluster communication. This protocol
originates from Ericsson where it has been used in carrier grade
cluster applications for many years.
For more information about TIPC, see http://tipc.sourceforge.net.
This protocol support is also available as a module ( = code which
can be inserted in and removed from the running kernel whenever you
want). The module will be called tipc. If you want to compile it
as a module, say M here and read <file:Documentation/kbuild/modules.txt>.
If in doubt, say N.
if TIPC
config TIPC_ADVANCED
bool "Advanced TIPC configuration"
default n
help
Saying Y here will open some advanced configuration for TIPC.
Most users do not need to bother; if unsure, just say N.
config TIPC_PORTS
int "Maximum number of ports in a node"
depends on TIPC_ADVANCED
range 127 65535
default "8191"
help
Specifies how many ports can be supported by a node.
Can range from 127 to 65535 ports; default is 8191.
Setting this to a smaller value saves some memory,
setting it to higher allows for more ports.
config TIPC_LOG
int "Size of log buffer"
depends on TIPC_ADVANCED
range 0 32768
default "0"
help
Size (in bytes) of TIPC's internal log buffer, which records the
occurrence of significant events. Can range from 0 to 32768 bytes;
default is 0.
There is no need to enable the log buffer unless the node will be
managed remotely via TIPC.
config TIPC_DEBUG
bool "Enable debugging support"
default n
help
Saying Y here enables TIPC debugging capabilities used by developers.
Most users do not need to bother; if unsure, just say N.
Enabling debugging support causes TIPC to display data about its
internal state when certain abnormal conditions occur. It also
makes it easy for developers to capture additional information of
interest using the dbg() or msg_dbg() macros.
endif # TIPC