c576e30cd0
Add support for voltage and current peak (historic maximum) attributes. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
64 lines
2 KiB
Text
64 lines
2 KiB
Text
Kernel driver adm1275
|
|
=====================
|
|
|
|
Supported chips:
|
|
* Analog Devices ADM1275
|
|
Prefix: 'adm1275'
|
|
Addresses scanned: -
|
|
Datasheet: www.analog.com/static/imported-files/data_sheets/ADM1275.pdf
|
|
|
|
Author: Guenter Roeck <guenter.roeck@ericsson.com>
|
|
|
|
|
|
Description
|
|
-----------
|
|
|
|
This driver supports hardware montoring for Analog Devices ADM1275 Hot-Swap
|
|
Controller and Digital Power Monitor.
|
|
|
|
The ADM1275 is a hot-swap controller that allows a circuit board to be removed
|
|
from or inserted into a live backplane. It also features current and voltage
|
|
readback via an integrated 12-bit analog-to-digital converter (ADC), accessed
|
|
using a PMBus. interface.
|
|
|
|
The driver is a client driver to the core PMBus driver. Please see
|
|
Documentation/hwmon/pmbus for details on PMBus client drivers.
|
|
|
|
|
|
Usage Notes
|
|
-----------
|
|
|
|
This driver does not auto-detect devices. You will have to instantiate the
|
|
devices explicitly. Please see Documentation/i2c/instantiating-devices for
|
|
details.
|
|
|
|
|
|
Platform data support
|
|
---------------------
|
|
|
|
The driver supports standard PMBus driver platform data. Please see
|
|
Documentation/hwmon/pmbus for details.
|
|
|
|
|
|
Sysfs entries
|
|
-------------
|
|
|
|
The following attributes are supported. Limits are read-write, history reset
|
|
attributes are write-only, all other attributes are read-only.
|
|
|
|
in1_label "vin1" or "vout1" depending on chip variant and
|
|
configuration.
|
|
in1_input Measured voltage. From READ_VOUT register.
|
|
in1_min Minumum Voltage. From VOUT_UV_WARN_LIMIT register.
|
|
in1_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
|
|
in1_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
|
|
in1_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
|
|
in1_highest Historical maximum voltage.
|
|
in1_reset_history Write any value to reset history.
|
|
|
|
curr1_label "iout1"
|
|
curr1_input Measured current. From READ_IOUT register.
|
|
curr1_max Maximum current. From IOUT_OC_WARN_LIMIT register.
|
|
curr1_max_alarm Current high alarm. From IOUT_OC_WARN_LIMIT register.
|
|
curr1_highest Historical maximum current.
|
|
curr1_reset_history Write any value to reset history.
|