Felix Beck 19b123ebac [S390] zcrypt: Do not remove coprocessor for error 8/72
In a case where the number of the input data is bigger than the
modulus of the key, the coprocessor adapters will report an 8/72
error. This case is not caught yet, thus the adapter will be taken
offline. To prevent this, we return an -EINVAL instead.

Signed-off-by: Felix Beck <felix.beck@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2010-01-27 10:12:49 +01:00
..