51f98a8d70
Eliminates routines, data structures, and files that were intended to allows TIPC to support a network containing multiple zones. Currently, TIPC supports only networks consisting of a single cluster within a single zone, so this code is unnecessary. Signed-off-by: Allan Stephens <Allan.Stephens@windriver.com> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>
88 lines
2.5 KiB
Text
88 lines
2.5 KiB
Text
#
|
|
# TIPC configuration
|
|
#
|
|
|
|
menuconfig TIPC
|
|
tristate "The TIPC Protocol (EXPERIMENTAL)"
|
|
depends on INET && EXPERIMENTAL
|
|
---help---
|
|
The Transparent Inter Process Communication (TIPC) protocol is
|
|
specially designed for intra cluster communication. This protocol
|
|
originates from Ericsson where it has been used in carrier grade
|
|
cluster applications for many years.
|
|
|
|
For more information about TIPC, see http://tipc.sourceforge.net.
|
|
|
|
This protocol support is also available as a module ( = code which
|
|
can be inserted in and removed from the running kernel whenever you
|
|
want). The module will be called tipc. If you want to compile it
|
|
as a module, say M here and read <file:Documentation/kbuild/modules.txt>.
|
|
|
|
If in doubt, say N.
|
|
|
|
if TIPC
|
|
|
|
config TIPC_ADVANCED
|
|
bool "Advanced TIPC configuration"
|
|
default n
|
|
help
|
|
Saying Y here will open some advanced configuration for TIPC.
|
|
Most users do not need to bother; if unsure, just say N.
|
|
|
|
config TIPC_CLUSTERS
|
|
int "Maximum number of clusters in a zone"
|
|
depends on TIPC_ADVANCED
|
|
range 1 1
|
|
default "1"
|
|
help
|
|
Specifies how many clusters can be supported in a TIPC zone.
|
|
|
|
*** Currently TIPC only supports a single cluster per zone. ***
|
|
|
|
config TIPC_NODES
|
|
int "Maximum number of nodes in a cluster"
|
|
depends on TIPC_ADVANCED
|
|
range 8 2047
|
|
default "255"
|
|
help
|
|
Specifies how many nodes can be supported in a TIPC cluster.
|
|
Can range from 8 to 2047 nodes; default is 255.
|
|
|
|
Setting this to a smaller value saves some memory;
|
|
setting it to higher allows for more nodes.
|
|
|
|
config TIPC_PORTS
|
|
int "Maximum number of ports in a node"
|
|
depends on TIPC_ADVANCED
|
|
range 127 65535
|
|
default "8191"
|
|
help
|
|
Specifies how many ports can be supported by a node.
|
|
Can range from 127 to 65535 ports; default is 8191.
|
|
|
|
Setting this to a smaller value saves some memory,
|
|
setting it to higher allows for more ports.
|
|
|
|
config TIPC_LOG
|
|
int "Size of log buffer"
|
|
depends on TIPC_ADVANCED
|
|
range 0 32768
|
|
default "0"
|
|
help
|
|
Size (in bytes) of TIPC's internal log buffer, which records the
|
|
occurrence of significant events. Can range from 0 to 32768 bytes;
|
|
default is 0.
|
|
|
|
There is no need to enable the log buffer unless the node will be
|
|
managed remotely via TIPC.
|
|
|
|
config TIPC_DEBUG
|
|
bool "Enable debug messages"
|
|
default n
|
|
help
|
|
This enables debugging of TIPC.
|
|
|
|
Only say Y here if you are having trouble with TIPC. It will
|
|
enable the display of detailed information about what is going on.
|
|
|
|
endif # TIPC
|