When bnx2/cnic/bnx2i drivers are loaded in certain order, bnx2i will
will not initialize the device correctly because 'hba->cnic' will be
NULL when bnx2i_start() is called from register_device() context.
Under this condition 'ifdown' and 'ifup' of associated network
interface is required to bring iscsi adapter state to ready state so
that it will accept iscsi connection setup within the chip
Initializing 'hba->cnic' before calling register_device() will fix
this issue
Signed-off-by: Michael Chan <mchan@broadcom.com>
Signed-off-by: Anil Veerabhadrappa <anilgv@broadcom.com>
Reviewed-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
instruct firmware to use driver/iscsid provided expected statsn field
while constructing login pdu header.
Initialize 'flags' to instruct chip to use driver/iscsid provided
ExpStatSN value while constructing iSCSI login PDU header
Signed-off-by: Eddie Wai <waie@broadcom.com>
Signed-off-by: Anil Veerabhadrappa <anilgv@broadcom.com>
Reviewed-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
If the scsi eh is running and then a FC LLD calls
fc_remote_port_delete, the SCSI commands sent from the eh will fail.
To prevent this, a FC LLD can call fc_block_scsi_eh from the eh
callback, blocking the eh thread until the dev_loss_tmo fires or the
remote port is available again.
If (e.g. for a multipathing setup) the dev_loss_tmo is set to a very
large value, thus preventing the scsi device removal , the scsi eh can
block for a long time. For multipathing, the fast_io_fail_tmo is then
set to a low value to detect path problems sooner.
This patch introduces a new return code FAST_IO_FAIL. The function
fc_block_scsi_eh now returns FAST_IO_FAIL when the fast_io_fail_tmo
fires. This indicates that the LLD terminated all pending I/O requests
and there are no more pending SCSI commands for the scsi eh to wait
for. This return code can be passed back to the scsi eh to stop the
escalation and finish the recovery process for this device.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The default is enabled since 7e47e5ca18.
Signed-off-by: Ferenc Wagner <wferi@niif.hu>
Acked-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The qla84xx_mgmt_cmd function supports multiple subcommands.
Some subcommands require DMA memory and some do not.
Therefore check before freeing DMA memory whether it is allocated or not.
Signed-off-by: Harish Zunjarrao <harish.zunjarrao@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
1. Segregate BSG interface specific code to new files.
2. Handle multiple vendor specific commands indepedently.
3. Reorganised support for reset, management and update FCoE firmware commands.
4. Fixed memory leak issue in Loopback.
5. Added new vendor command to support iiDMA using BSG interface.
6. Proper cleanup of dma mapped and dma allocated buffers for BSG request.
[jejb: fix up conflict and merge in Jiri Slaby lock imbalance patch]
Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Signed-off-by: Harish Zunjarrao <harish.zunjarrao@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
sg address in IO request is not set up correctly for big endian platform.
add new macros to properly swap the address.
Signed-off-by: Jing Huang <huangj@brocade.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
idr is a global resource, protect it with global bfad_mutex.
Signed-off-by: Jing Huang <huangj@brocade.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Use pci_iomap() and pci_iounmap() to simplify the code. Remove uncessary #ifdef
check for ia64 (it was added as a workaound for some RHEL 5.x release which
doesn't export iounmap function)
Signed-off-by: Jing Huang <huangj@brocade.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Currently the driver doesn't take into consideraion of possible sg chaining
when it walks through the sg list. This is fixed by using the sg_next()
which automatically handles the chaining case. Obosolete code is removed
as a result of this change.
Signed-off-by: Jing Huang <huangj@brocade.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Use duplicate fc transport template for physical and vitual port. Add
vport create/delete/disalbe functions in the transport template of physical
port. Changes to make the vport create/delete function to work under this
framework.
Signed-off-by: Jing Huang <huangj@brocade.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch (as1359) fixes a bug in scsi_alloc_target(). After a
device structure has been initialized (and especially after its name
has been set), it must not be freed directly. One has to call
put_device() instead.
Signed-off-by: Alan Stern <stern@rowland.harvard.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch (as1358) fixes a bug in the error pathway of
scsi_target_add(). If registration fails, the target should not be
reaped. The reaping occurs later, when scanning is finished and all
the child devices are removed. The current code leaves an unbalanced
value in starget->reap_ref.
Signed-off-by: Alan Stern <stern@rowland.harvard.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
RAID_SCSI_IO_PASSTHROUGH: Driver needs to be send the default
descriptor for RAID Passthru, currently its sending SCSI_IO descriptor.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Added proper return type values in case memory allocation failed.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Removed all the mutex's for ioc->tm_cmds.mutex, then created one
single mutex inside the function mpt2sas_scsih_issue_tm. This is the
single function used when sending task management. Also the sanity
checks required for scsi mid layer escalation were moved to inside the
same function because these checks need to be done while the mutex is
held. The ioc->tm_cmds.mutex inside the IOCTL branch is really not
required since there is another mutex in this code called for ctl_cmds
handling this sync.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
1. Fixes for little endian issues.
2. Now Debug info for Discovery event is more readable.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Now Driver will not treat NEEDS_INIT as failure. In addition to this,
the driver will now display message to describe the the access flags
when bits are set, so the end user can better understand failures.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Aded checks for shost_recovery flag for early return from function.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
use the get_free_pages API for larger contigious physical memory chunk.
Also, the ioc->chain_depth need to be changed from
a 16bit to 32bit variable because the number of chains will exceed 64k
when the queue depth is large.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
bug fix in the handling of the internal device reset event
The reason code check in scsih_sas_device_status_change_event never
evaluates as true for internal device reset, hence driver never quiesce s IO
when firmware is sending a device reset. The fix is to change the
evaluate to:
if (event_data->ReasonCode !=
MPI2_EVENT_SAS_DEV_STAT_RC_INTERNAL_DEVICE_RESET &&
event_data->ReasonCode !=
MPI2_EVENT_SAS_DEV_STAT_RC_CMP_INTERNAL_DEV_RESET)
return;
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
incorrect timestamp on 32 bit platforms: The upper 32 bit of
the timestamp was getting truncated when converting seconds to
milliseconds, which was due to the variable being long. To fix the problem,
the variable needs to be u64. Also the microseconds conversion to
milliseconds was incorrect; it should be divide by 1000 instead of divide by
8.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Setting handle to zero is not required before _scsih_remove_device.
Driver uses sas_device->handle reference in _scsih_remove_device.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Enable NPIV by default.
- Added code to handle unsolicited LOGO on physical port.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Only abort outstanding I/O to force the OS to retry failed I/Os for AER
uncorrectable non-fatal errors instead of reseting the adapter.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Add BSG support for PCI loopback testing.
- Add BSG support for extended mailbox commands.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Correct all SLI4 code to work on big endian systems.
- Move read of sli4 params earlier so returned values are used correctly.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
FCF failover improvements
- Add random FCF failover when there are multiple FCFs available.
- Prevent FCF log messages from being displayed for FC adapters.
- Separate the New FCF and Modified FCF log messages.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When the kernel is configured for preemption, using smp_processor_id()
when preemption is enabled causes a warning backtrace and is wrong
since we could move off of that CPU as soon as we get the ID,
and we would be referencing the wrong CPU, and possibly an invalid one
if it could be hotswapped out.
Remove the fc_lport_get_stats() function and explicitly use per_cpu_ptr()
to get the statistics. Where preemption has been disabled by holding
a _bh lock continue to use smp_processor_id(), but otherwise use
get_cpu()/put_cpu().
In fcoe_recv_frame() also changed the cases where we return in the
middle to do a goto to the code which bumps ErrorFrames and does
a put_cpu(). Two of these cases didn't bump ErrorFrames before, but
doing so is harmless because they "can't happen", due to prior length
checks.
Also rearranged code in fcoe_recv_frame() to have only one call to
fc_exch_recv(). It's just as efficient and saves a call to put_cpu().
In fc_fcp.c, adjusted a FIXME comment for code which doesn't need fixing.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
DID_ERROR cases can be ambigouos. Debugging FCP error cases
will be much easier if we have debug statements when we hit
these error conditions.
This patch simply adds debug messages using the FC_FCP_DBG
macro when we return DID_ERROR to SCSI. This way if a DID_ERROR
is reproducible turning on debug_logging will give a clue
to developers as to what the problem might be.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Currently fc_fcp_recv_data calls fc_fcp_retry_cmd to
retry failed IO but in this case tgt is still sending
data frames, therefore exchange needs to be aborted
first before initiating retry. So this patch fixes
this by aborting exchange first then have retry.
Renames fc_timeout_error to fc_fcp_recovery since
fc_timeout_error is already called from several other
places beside from fcp timeout handler and then
used fc_fcp_recovery for abort & retry from
fc_fcp_recv_data, this rename also required renaming
FC_CMD_TIME_OUT status to FC_CMD_RECOVERY to be
consistent with new fc_fcp_recovery.
Data frames are not expected for an DDPed exchange and
potentially it could be tampered data frame, so does
recovery in this case by calling fc_fcp_recovery.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Since use of offloads is more efficient than switching
to non-offload EM. However kept logic same to call em_match
if it is provided in the list of EMs.
Converted fc_exch_alloc to inline being now tiny a function
and already not an exported libfc API any more.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In some cases seq is incremented twice causing unnecessary
seq jump, for instance fc_exch_recv_seq_resp increments
seq id when fc_sof_is_init is true and that is true for
each incoming xfer ready but then fc_fcp_send_data does
another seq increment to send data for xfer ready.
This patch removes all such seq id jumps, at least it
eliminates few calls to fc_seq_start_next using ex_lock.
Also removes seq id update with incoming frame's seq id
as this is not needed since each end (I or T) just need
to send incremented their own seq id on each TSI from
other end & before sending new sequence within a
exchange.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When starting a new response sequence in a multi-sequence
exchange, a warning was issued that sequence initiative
wasn't held.
The bug was that sequence initiative was cleared by the previous
sequence due to the END_SEQ flag being on. The intent may have
been to check LAST_SEQ. Change just to check SEQ_INIT.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The link and last_link fields in the fcoe_ctlr struct are no
longer useful, since they are always set to the same value,
and FIP always calls libfc to pass link information to the lport.
Eliminate those fields and rename link_work to timer_work, since
it no longer has any link change work to do.
Thanks to Brian Uchino for discovering this issue.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Remove an unused variable, mac, in fcoe_recv_frame().
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The method we've been using for point-to-point mode requires
that the LS_ACC for the FLOGI uses the D_ID and S_ID assigned
to the remote port and local port, not those in the exchange.
This is not the correct method, but for now, it's what works
with the old target, as well as with new targets based on libfc.
This patch changes the addresses used accordingly.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When receiving a FLOGI request from a point-to-point peer,
the D_ID of 0xfffffe was not recognized as belonging to one
of the lports, so it was dropped.
Change fc_vport_id_lookup() to treat d_id 0xfffffe as a match.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In point-to-point mode, we need to save the source MAC
from received FLOGI requests to use as the destination MAC
for all outgoing frames. We stopped doing that at some point.
Use the lport_set_port_id method to catch incoming FLOGI frames
and pass them to fcoe_ctlr_recv_flogi() so it can save the source MAC.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The debug message that indicated we are using non-FIP mode was
being printed only if we were already in non-FIP mode.
Also changed the message text to make it more clear the mode
is being set, not that the message is indicating how FLOGI
was received.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In point-to-point mode, the destination MAC address for
the FLOGI response was zero because the LS_ACC for the FLOGI
wasn't getting intercepted by FIP.
Change to call fcoe_ctlr_els_send when sending any ELS,
not just requests.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In point-to-point mode, if the PLOGI to the remote port times
out, it can get deleted by the remote port module. Since there's
no reference by the local port, lport->ptp_data points to a freed
rport, and when the local port is reset and tries to logout again,
an oops occurs in mutex_lock_nested().
Hold a reference count on the point-to-point rdata.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Reduce indentation in fc_rport_recv_prli_req() using gotos.
Also add payload length checks.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>