Commit graph

12 commits

Author SHA1 Message Date
Chanwoo Choi
2ed9e9b653 charger-manager: Check fully charged state of battery periodically
This patch check periodically fully charged state of battery to protect
overcharge and overheat. If battery is fully charged, stop charging and
check droped voltage with 'fullbatt_vchkdrop_ms' period. When voltage of
battery is more droped than 'fullbatt_vchkdrop_uV' voltage,
charger-manager will restart charging for battery.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-09-20 22:07:49 -07:00
Chanwoo Choi
fd65ee5f1c charger-manager: Use replacement variable to check state of battery
This patch remove unnecessary variable(cm->fullbatt_vchk_uV) by using
'desc->fullbatt_uV' field directly in fullbatt_handler() function
to check the state of battery.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-08-22 20:09:08 -07:00
Chanwoo Choi
dbb61fc745 charger-manager: Disable regulator when charger cable is detached
This patch disable regulator for charging when charger cable is detached
before stopping charging forcibly on abnormal battery state and check
return value of regulator_enable/disable() function to confirm correct
operation of enabling or disabling regulator for charging.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-08-22 20:08:28 -07:00
Chanwoo Choi
45cd4fb28b charger-manager: Set current limit of regulator for over current protection
This patch support the protection of host device from over current.
The Charger-manager set proper current limit of charger(regulator) for
charging according to type of charger cable when external connector
is attached.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-07-13 18:31:17 -07:00
Chanwoo Choi
bee737bccb charger-manager: Use EXTCON Subsystem to detect charger cables for charging
This patch support that charger-manager use EXTCON(External Connector)
Subsystem to detect the state of charger cables for enabling or disabling
charger(regulator) and select the charger cable for charging among
a number of external cable according to policy of H/W board.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-07-13 18:31:13 -07:00
Chanwoo Choi
dfeccb12b4 charger-manager: Provide cm_notify_event function for in-kernel use
By using cm_notify_event function, charger driver can report several
charger events (e.g. battery full and external power in/out, etc) to
Charger-Manager. Charger-Manager can properly and immediately control
chargers by the reported event.

Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-05-05 19:51:58 -07:00
Chanwoo Choi
d829dc75ba charger-manager: Poll battery health in normal state
Charger-Manager needs to check battery health in normal state
as well as suspend-to-RAM state. When the battery is fully charged,
Charger-Manager needs to determine when the chargers restart charging.

This patch allows Charger-Manager to monitor battery health in normal
state and handle operation for chargers after battery is fully charged.

Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-05-05 19:48:50 -07:00
Anton Vorontsov
df58c04c9f charger-manager: Simplify charger_get_property(), get rid of a warning
This patch fixes the following warning and makes the code a little
bit more simpler:

  CC      drivers/power/charger-manager.o
charger-manager.c: In function 'charger_get_property':
charger-manager.c:429:15: warning: 'i' may be used uninitialized in this function [-Wuninitialized]

Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-03-26 20:41:20 +04:00
Axel Lin
bb2a95c2d2 charger-manager: Clean up for better readability
This patch includes below changes:

* Some code change for better readability.
* Current code in probe already ensures desc->charger_regulators
  is not NULL. No need to check if it is NULL or not before calling
  regulator_bulk_free().
* Use dev_get_drvdata() in cm_suspend_prepare() and cm_suspend_complete()

Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-03-26 20:41:19 +04:00
Axel Lin
1bbe24d465 power_supply: Fix modalias for charger-manager
Since 43cc71eed1, the platform
modalias is prefixed with "platform:".
Current code has the id_table, thus add MODULE_DEVICE_TABLE will
automatically setup the modalias.

Also make charger_manager_id static as it is only used in this driver.

Signed-off-by: Axel Lin <axel.lin@gmail.com>
Acked-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
2012-02-01 21:29:52 +04:00
Donggeun Kim
ad3d13eee7 power_supply: Charger-Manager: Add properties for power-supply-class
Charger Manager provides power-supply-class aggregating
information from multiple chargers and a fuel-gauge.

Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
2012-01-04 08:08:45 +04:00
Donggeun Kim
3bb3dbbd56 power_supply: Add initial Charger-Manager driver
Because battery health monitoring should be done even when suspended,
it needs to wake up and suspend periodically. Thus, userspace battery
monitoring may incur too much overhead; every device and task is woken
up periodically. Charger Manager uses suspend-again to provide
in-suspend monitoring.

This patch allows to monitor battery health in-suspend state.

Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
2012-01-04 08:08:27 +04:00