powerpc/windfarm: Fix noisy slots-fan on Xserve (rm31)
slots-fan on G5 Xserve is always running at full speed with windfarm_rm31 driver, resulting in a very high acoustic noise level. It seems the fan parameters are incorrect, and have been copied from the Drive Bay fan (RPM, not present on rm31) of the legacy therm_pm72 driver. This patch changes the parameters to match the Slots fan (PWM) of therm_pm72. With the patch, slots-fan speed drops from 99% to 19% during normal use, and slots-temp settle to ~42'C. Signed-off-by: Aaro Koskinen <aaro.koskinen@iki.fi> CC: <stable@vger.kernel.org> Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
This commit is contained in:
parent
3be7db6ab4
commit
fe956a1d40
1 changed files with 9 additions and 9 deletions
|
@ -439,15 +439,15 @@ static void backside_setup_pid(void)
|
|||
|
||||
/* Slots fan */
|
||||
static const struct wf_pid_param slots_param = {
|
||||
.interval = 5,
|
||||
.history_len = 2,
|
||||
.gd = 30 << 20,
|
||||
.gp = 5 << 20,
|
||||
.gr = 0,
|
||||
.itarget = 40 << 16,
|
||||
.additive = 1,
|
||||
.min = 300,
|
||||
.max = 4000,
|
||||
.interval = 1,
|
||||
.history_len = 20,
|
||||
.gd = 0,
|
||||
.gp = 0,
|
||||
.gr = 0x00100000,
|
||||
.itarget = 3200000,
|
||||
.additive = 0,
|
||||
.min = 20,
|
||||
.max = 100,
|
||||
};
|
||||
|
||||