tracing/syscalls: Fix typo in SYSCALL_DEFINE0
The struct syscall_metadata variable name in SYSCALL_DEFINE0 should be __syscall_meta__##sname instead of __syscall_meta_##sname to match the name that is in SYSCALL_DEFINE1/2/3/4/5/6. This error causes event_enter_##sname->data to point to the wrong location, which causes syscalls which are defined by SYSCALL_DEFINE0() not to be traced. Signed-off-by: Lai Jiangshan <laijs@cn.fujitsu.com> LKML-Reference: <4B273D2E.1010807@cn.fujitsu.com> Acked-by: Frederic Weisbecker <fweisbec@gmail.com> Signed-off-by: Steven Rostedt <rostedt@goodmis.org>
This commit is contained in:
parent
79b4082108
commit
e96dc9674c
1 changed files with 1 additions and 1 deletions
|
@ -195,7 +195,7 @@ struct perf_event_attr;
|
|||
static const struct syscall_metadata __used \
|
||||
__attribute__((__aligned__(4))) \
|
||||
__attribute__((section("__syscalls_metadata"))) \
|
||||
__syscall_meta_##sname = { \
|
||||
__syscall_meta__##sname = { \
|
||||
.name = "sys_"#sname, \
|
||||
.nb_args = 0, \
|
||||
.enter_event = &event_enter__##sname, \
|
||||
|
|
Loading…