platform/x86: pmc_atom: Add several Beckhoff Automation boards to critclk_systems DMI table
[ Upstream commit d6423bd03031c020121da26c41a26bd5cc6d0da3 ]
There are several Beckhoff Automation industrial PC boards which use
pmc_plt_clk* clocks for ethernet controllers. This adds affected boards
to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and
not turned off.
Fixes: 648e921888
("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
parent
1a80d9ff82
commit
d7a32c8a1c
1 changed files with 24 additions and 0 deletions
|
@ -413,6 +413,30 @@ static const struct dmi_system_id critclk_systems[] = {
|
|||
DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Beckhoff CB3163",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
|
||||
DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Beckhoff CB6263",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
|
||||
DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
|
||||
},
|
||||
},
|
||||
{
|
||||
/* pmc_plt_clk* - are used for ethernet controllers */
|
||||
.ident = "Beckhoff CB6363",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
|
||||
DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
|
||||
},
|
||||
},
|
||||
{ /*sentinel*/ }
|
||||
};
|
||||
|
||||
|
|