V4L/DVB (5495): Tda10086: fix DiSEqC message length
Setting the message length to zero means to send one byte, so you need a subtraction instead of an addition. Signed-off-by: Andreas Oberritter <obi@linuxtv.org> Signed-off-by: Mauro Carvalho Chehab <mchehab@infradead.org>
This commit is contained in:
parent
2e175a9004
commit
d420cb4469
1 changed files with 1 additions and 1 deletions
|
@ -212,7 +212,7 @@ static int tda10086_send_master_cmd (struct dvb_frontend* fe,
|
|||
for(i=0; i< cmd->msg_len; i++) {
|
||||
tda10086_write_byte(state, 0x48+i, cmd->msg[i]);
|
||||
}
|
||||
tda10086_write_byte(state, 0x36, 0x08 | ((cmd->msg_len + 1) << 4));
|
||||
tda10086_write_byte(state, 0x36, 0x08 | ((cmd->msg_len - 1) << 4));
|
||||
|
||||
tda10086_diseqc_wait(state);
|
||||
|
||||
|
|