drivers: PL011: allow to supply fixed option string

The SBSA UART has a fixed baud rate and flow control setting, which
cannot be changed or queried by software.
Add a vendor specific property to always return fixed values when
trying to read the console options.

Signed-off-by: Andre Przywara <andre.przywara@arm.com>
Tested-by: Mark Langsdorf <mlangsdo@redhat.com>
Tested-by: Naresh Bhat <nbhat@cavium.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Andre Przywara 2015-05-21 17:26:22 +01:00 committed by Greg Kroah-Hartman
parent 71eec4836b
commit cefc2d1d66

View file

@ -79,6 +79,7 @@ struct vendor_data {
bool dma_threshold;
bool cts_event_workaround;
bool always_enabled;
bool fixed_options;
unsigned int (*get_fifosize)(struct amba_device *dev);
};
@ -96,6 +97,7 @@ static struct vendor_data vendor_arm = {
.dma_threshold = false,
.cts_event_workaround = false,
.always_enabled = false,
.fixed_options = false,
.get_fifosize = get_fifosize_arm,
};
@ -112,6 +114,7 @@ static struct vendor_data vendor_st = {
.dma_threshold = true,
.cts_event_workaround = true,
.always_enabled = false,
.fixed_options = false,
.get_fifosize = get_fifosize_st,
};
@ -160,6 +163,7 @@ struct uart_amba_port {
unsigned int lcrh_rx; /* vendor-specific */
unsigned int old_cr; /* state during shutdown */
bool autorts;
unsigned int fixed_baud; /* vendor-set fixed baud rate */
char type[12];
#ifdef CONFIG_DMA_ENGINE
/* DMA stuff */
@ -2076,10 +2080,15 @@ static int __init pl011_console_setup(struct console *co, char *options)
uap->port.uartclk = clk_get_rate(uap->clk);
if (options)
uart_parse_options(options, &baud, &parity, &bits, &flow);
else
pl011_console_get_options(uap, &baud, &parity, &bits);
if (uap->vendor->fixed_options) {
baud = uap->fixed_baud;
} else {
if (options)
uart_parse_options(options,
&baud, &parity, &bits, &flow);
else
pl011_console_get_options(uap, &baud, &parity, &bits);
}
return uart_set_options(&uap->port, co, baud, parity, bits, flow);
}