regulator: wm831x-ldo: Use regulator_map_voltage_linear for wm831x_alive_ldo_ops
wm831x_alive_ldo_ops uses simple linear voltage maps. Thus use regulator_map_voltage_linear is more efficient than using the default regulator_map_voltage_iterate. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
parent
f2d103add1
commit
c2543b5f6c
1 changed files with 1 additions and 0 deletions
|
@ -690,6 +690,7 @@ static int wm831x_alive_ldo_get_status(struct regulator_dev *rdev)
|
|||
|
||||
static struct regulator_ops wm831x_alive_ldo_ops = {
|
||||
.list_voltage = regulator_list_voltage_linear,
|
||||
.map_voltage = regulator_map_voltage_linear,
|
||||
.get_voltage_sel = regulator_get_voltage_sel_regmap,
|
||||
.set_voltage = wm831x_alive_ldo_set_voltage,
|
||||
.set_suspend_voltage = wm831x_alive_ldo_set_suspend_voltage,
|
||||
|
|
Loading…
Reference in a new issue