ARM: ux300: Fix unimplementable regulation constraints

It doesn't make sense to grant permission to change the status of a
regulator that is also set as always on and similarly it doesn't make
sense to allow a driver to change the voltage of a regulator which can
only be set to a single voltage.

Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
This commit is contained in:
Mark Brown 2012-03-31 17:44:53 +01:00 committed by Linus Walleij
parent e816b57a33
commit a102962ffd

View file

@ -146,9 +146,6 @@ static struct ab3100_platform_data ab3100_plf_data = {
.min_uV = 1800000,
.max_uV = 1800000,
.valid_modes_mask = REGULATOR_MODE_NORMAL,
.valid_ops_mask =
REGULATOR_CHANGE_VOLTAGE |
REGULATOR_CHANGE_STATUS,
.always_on = 1,
.boot_on = 1,
},
@ -160,9 +157,6 @@ static struct ab3100_platform_data ab3100_plf_data = {
.min_uV = 2500000,
.max_uV = 2500000,
.valid_modes_mask = REGULATOR_MODE_NORMAL,
.valid_ops_mask =
REGULATOR_CHANGE_VOLTAGE |
REGULATOR_CHANGE_STATUS,
.always_on = 1,
.boot_on = 1,
},
@ -230,8 +224,7 @@ static struct ab3100_platform_data ab3100_plf_data = {
.max_uV = 1800000,
.valid_modes_mask = REGULATOR_MODE_NORMAL,
.valid_ops_mask =
REGULATOR_CHANGE_VOLTAGE |
REGULATOR_CHANGE_STATUS,
REGULATOR_CHANGE_VOLTAGE,
.always_on = 1,
.boot_on = 1,
},