olpc_battery: Ensure that the TRICKLE bit is checked
There are times when the battery is present but trickle charging, and the EC sets only the TRICKLE bit. So we must check for the bit when we're checking the charging/present status. Signed-off-by: Andres Salomon <dilinger@collabora.co.uk> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This commit is contained in:
parent
04a820ead0
commit
8f7e57985f
1 changed files with 6 additions and 3 deletions
|
@ -36,6 +36,7 @@
|
|||
#define BAT_STAT_AC 0x10
|
||||
#define BAT_STAT_CHARGING 0x20
|
||||
#define BAT_STAT_DISCHARGING 0x40
|
||||
#define BAT_STAT_TRICKLE 0x80
|
||||
|
||||
#define BAT_ERR_INFOFAIL 0x02
|
||||
#define BAT_ERR_OVERVOLTAGE 0x04
|
||||
|
@ -90,7 +91,7 @@ static char bat_serial[17]; /* Ick */
|
|||
static int olpc_bat_get_status(union power_supply_propval *val, uint8_t ec_byte)
|
||||
{
|
||||
if (olpc_platform_info.ecver > 0x44) {
|
||||
if (ec_byte & BAT_STAT_CHARGING)
|
||||
if (ec_byte & (BAT_STAT_CHARGING | BAT_STAT_TRICKLE))
|
||||
val->intval = POWER_SUPPLY_STATUS_CHARGING;
|
||||
else if (ec_byte & BAT_STAT_DISCHARGING)
|
||||
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
|
||||
|
@ -220,7 +221,8 @@ static int olpc_bat_get_property(struct power_supply *psy,
|
|||
It doesn't matter though -- the EC will return the last-known
|
||||
information, and it's as if we just ran that _little_ bit faster
|
||||
and managed to read it out before the battery went away. */
|
||||
if (!(ec_byte & BAT_STAT_PRESENT) && psp != POWER_SUPPLY_PROP_PRESENT)
|
||||
if (!(ec_byte & (BAT_STAT_PRESENT | BAT_STAT_TRICKLE)) &&
|
||||
psp != POWER_SUPPLY_PROP_PRESENT)
|
||||
return -ENODEV;
|
||||
|
||||
switch (psp) {
|
||||
|
@ -230,7 +232,8 @@ static int olpc_bat_get_property(struct power_supply *psy,
|
|||
return ret;
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_PRESENT:
|
||||
val->intval = !!(ec_byte & BAT_STAT_PRESENT);
|
||||
val->intval = !!(ec_byte & (BAT_STAT_PRESENT |
|
||||
BAT_STAT_TRICKLE));
|
||||
break;
|
||||
|
||||
case POWER_SUPPLY_PROP_HEALTH:
|
||||
|
|
Loading…
Reference in a new issue