iio:adis16400: Add support for the 52.85 Hz base sampling rate
The adis16400 and similar have two different base sampling rate available, from which the actual sampling rate is derived. 1638 Hz and 52.85 Hz, switching to the lower base sampling rate allows to support lower sampling rates. This patch adds support for switching to the lower base sampling rate if the requested sampling frequency is outside of the range which can be supported by the higher base sampling rate. The function which is used to read the current sampling rate already has support for the lower sampling rate, so no changes are required there. Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
parent
b24150e31a
commit
7ba8a04dcd
1 changed files with 12 additions and 4 deletions
|
@ -92,18 +92,26 @@ static int adis16400_get_freq(struct adis16400_state *st)
|
|||
static int adis16400_set_freq(struct adis16400_state *st, unsigned int freq)
|
||||
{
|
||||
unsigned int t;
|
||||
uint8_t val = 0;
|
||||
|
||||
t = 1638404 / freq;
|
||||
if (t > 0)
|
||||
if (t >= 128) {
|
||||
val |= ADIS16400_SMPL_PRD_TIME_BASE;
|
||||
t = 52851 / freq;
|
||||
if (t >= 128)
|
||||
t = 127;
|
||||
} else if (t != 0) {
|
||||
t--;
|
||||
t &= ADIS16400_SMPL_PRD_DIV_MASK;
|
||||
}
|
||||
|
||||
if ((t & ADIS16400_SMPL_PRD_DIV_MASK) >= 0x0A)
|
||||
val |= t;
|
||||
|
||||
if (t >= 0x0A || (val & ADIS16400_SMPL_PRD_TIME_BASE))
|
||||
st->adis.spi->max_speed_hz = ADIS16400_SPI_SLOW;
|
||||
else
|
||||
st->adis.spi->max_speed_hz = ADIS16400_SPI_FAST;
|
||||
|
||||
return adis_write_reg_8(&st->adis, ADIS16400_SMPL_PRD, t);
|
||||
return adis_write_reg_8(&st->adis, ADIS16400_SMPL_PRD, val);
|
||||
}
|
||||
|
||||
static ssize_t adis16400_read_frequency(struct device *dev,
|
||||
|
|
Loading…