[SCSI] ibmvfc: Ignore fabric RSCNs when link is dead

This fixes an issues seen where a Fabric RSCN event was received
while the link was down, which resulted in repeated attempts to log back
into the fabric, which then failed, resulting in the ibmvfc driver
taking the host offline. Fix this by delaying taking any action
regarding the fabric RSCN until the link comes back up.

Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
This commit is contained in:
Brian King 2012-08-24 16:51:01 -05:00 committed by James Bottomley
parent a077c7faf3
commit 5cdf162654

View file

@ -2625,8 +2625,10 @@ static void ibmvfc_handle_async(struct ibmvfc_async_crq *crq,
case IBMVFC_AE_SCN_FABRIC:
case IBMVFC_AE_SCN_DOMAIN:
vhost->events_to_log |= IBMVFC_AE_RSCN;
vhost->delay_init = 1;
__ibmvfc_reset_host(vhost);
if (vhost->state < IBMVFC_HALTED) {
vhost->delay_init = 1;
__ibmvfc_reset_host(vhost);
}
break;
case IBMVFC_AE_SCN_NPORT:
case IBMVFC_AE_SCN_GROUP: