ARM: mach-shmobile: do not enable the PLLC2 clock on init
AP4EVB has to reparent PLLC2 to provide a precise HDMI clock, this is only possible, if PLLC2 hasn't been enabled yet. Since no other driver currently uses PLLC2 we can safely remove the CLK_ENABLE_ON_INIT flag. This fixes the "Cannot set PLLC2 parent: -16, 1 users" error message, when trying to use HDMI on AP4EVB. Signed-off-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de> Signed-off-by: Paul Mundt <lethal@linux-sh.org>
This commit is contained in:
parent
3572b33efb
commit
4e1774f3a5
1 changed files with 0 additions and 1 deletions
|
@ -286,7 +286,6 @@ static struct clk_ops pllc2_clk_ops = {
|
|||
|
||||
struct clk pllc2_clk = {
|
||||
.ops = &pllc2_clk_ops,
|
||||
.flags = CLK_ENABLE_ON_INIT,
|
||||
.parent = &extal1_div2_clk,
|
||||
.freq_table = pllc2_freq_table,
|
||||
.parent_table = pllc2_parent,
|
||||
|
|
Loading…