serial: omap-serial: Move info message to probe function
Currently the info message about a missing wakeirq for uart is printed every time the serial driver's startup function is called. This happens multiple times and not just once. This patch moves the infomessage to the probe function to display it only once. Acked-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Markus Pargmann <mpa@pengutronix.de> Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
f7e54d7ad7
commit
4a818a09c0
1 changed files with 3 additions and 3 deletions
|
@ -738,9 +738,6 @@ static int serial_omap_startup(struct uart_port *port)
|
|||
return retval;
|
||||
}
|
||||
disable_irq(up->wakeirq);
|
||||
} else {
|
||||
dev_info(up->port.dev, "no wakeirq for uart%d\n",
|
||||
up->port.line);
|
||||
}
|
||||
|
||||
dev_dbg(up->port.dev, "serial_omap_startup+%d\n", up->port.line);
|
||||
|
@ -1687,6 +1684,9 @@ static int serial_omap_probe(struct platform_device *pdev)
|
|||
up->port.iotype = UPIO_MEM;
|
||||
up->port.irq = uartirq;
|
||||
up->wakeirq = wakeirq;
|
||||
if (!up->wakeirq)
|
||||
dev_info(up->port.dev, "no wakeirq for uart%d\n",
|
||||
up->port.line);
|
||||
|
||||
up->port.regshift = 2;
|
||||
up->port.fifosize = 64;
|
||||
|
|
Loading…