ARM: EXYNOS: Correct M-5MOLS sensor clock frequency on Universal C210 board
In order to keep the sensor's master clock frequency in valid range when FIMC parent clock is xusbxti, the specified frequency must be exactly 24MHZ, otherwise it's being set to too low value due to rounding. Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
This commit is contained in:
parent
7cc98aaea4
commit
3e8ad5610c
1 changed files with 1 additions and 1 deletions
|
@ -910,7 +910,7 @@ static struct s5p_fimc_isp_info universal_camera_sensors[] = {
|
|||
.bus_type = FIMC_MIPI_CSI2,
|
||||
.board_info = &m5mols_board_info,
|
||||
.i2c_bus_num = 0,
|
||||
.clk_frequency = 21600000UL,
|
||||
.clk_frequency = 24000000UL,
|
||||
.csi_data_align = 32,
|
||||
},
|
||||
};
|
||||
|
|
Loading…