ARM: EXYNOS: Correct M-5MOLS sensor clock frequency on Universal C210 board

In order to keep the sensor's master clock frequency in valid range
when FIMC parent clock is xusbxti, the specified frequency must be
exactly 24MHZ, otherwise it's being set to too low value due to
rounding.

Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
This commit is contained in:
Sylwester Nawrocki 2012-01-31 12:58:31 +09:00 committed by Kukjin Kim
parent 7cc98aaea4
commit 3e8ad5610c

View file

@ -910,7 +910,7 @@ static struct s5p_fimc_isp_info universal_camera_sensors[] = {
.bus_type = FIMC_MIPI_CSI2,
.board_info = &m5mols_board_info,
.i2c_bus_num = 0,
.clk_frequency = 21600000UL,
.clk_frequency = 24000000UL,
.csi_data_align = 32,
},
};