hwmon: (htu21) Remove driver
HTU21 is now supported by IIO, and can be instantiated as hwmon driver using the iio-hwmon bridge. An explicit hwmon driver is no longer needed. Cc: William Markezana <william.markezana@meas-spec.com> Cc: Ludovic Tancerel <ludovic.tancerel@maplehightech.com> Cc: Jonathan Cameron <jic23@kernel.org> Reviewed-by: Jean Delvare <jdelvare@suse.de> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
a3a316cfc4
commit
2ff44072e3
4 changed files with 0 additions and 231 deletions
|
@ -1,46 +0,0 @@
|
|||
Kernel driver htu21
|
||||
===================
|
||||
|
||||
Supported chips:
|
||||
* Measurement Specialties HTU21D
|
||||
Prefix: 'htu21'
|
||||
Addresses scanned: none
|
||||
Datasheet: Publicly available at the Measurement Specialties website
|
||||
http://www.meas-spec.com/downloads/HTU21D.pdf
|
||||
|
||||
|
||||
Author:
|
||||
William Markezana <william.markezana@meas-spec.com>
|
||||
|
||||
Description
|
||||
-----------
|
||||
|
||||
The HTU21D is a humidity and temperature sensor in a DFN package of
|
||||
only 3 x 3 mm footprint and 0.9 mm height.
|
||||
|
||||
The devices communicate with the I2C protocol. All sensors are set to the
|
||||
same I2C address 0x40, so an entry with I2C_BOARD_INFO("htu21", 0x40) can
|
||||
be used in the board setup code.
|
||||
|
||||
This driver does not auto-detect devices. You will have to instantiate the
|
||||
devices explicitly. Please see Documentation/i2c/instantiating-devices
|
||||
for details.
|
||||
|
||||
sysfs-Interface
|
||||
---------------
|
||||
|
||||
temp1_input - temperature input
|
||||
humidity1_input - humidity input
|
||||
|
||||
Notes
|
||||
-----
|
||||
|
||||
The driver uses the default resolution settings of 12 bit for humidity and 14
|
||||
bit for temperature, which results in typical measurement times of 11 ms for
|
||||
humidity and 44 ms for temperature. To keep self heating below 0.1 degree
|
||||
Celsius, the device should not be active for more than 10% of the time. For
|
||||
this reason, the driver performs no more than two measurements per second and
|
||||
reports cached information if polled more frequently.
|
||||
|
||||
Different resolutions, the on-chip heater, using the CRC checksum and reading
|
||||
the serial number are not supported yet.
|
|
@ -859,16 +859,6 @@ config SENSORS_MAX31790
|
|||
This driver can also be built as a module. If so, the module
|
||||
will be called max31790.
|
||||
|
||||
config SENSORS_HTU21
|
||||
tristate "Measurement Specialties HTU21D humidity/temperature sensors"
|
||||
depends on I2C
|
||||
help
|
||||
If you say yes here you get support for the Measurement Specialties
|
||||
HTU21D humidity and temperature sensors.
|
||||
|
||||
This driver can also be built as a module. If so, the module
|
||||
will be called htu21.
|
||||
|
||||
config SENSORS_MCP3021
|
||||
tristate "Microchip MCP3021 and compatibles"
|
||||
depends on I2C
|
||||
|
|
|
@ -68,7 +68,6 @@ obj-$(CONFIG_SENSORS_GL518SM) += gl518sm.o
|
|||
obj-$(CONFIG_SENSORS_GL520SM) += gl520sm.o
|
||||
obj-$(CONFIG_SENSORS_GPIO_FAN) += gpio-fan.o
|
||||
obj-$(CONFIG_SENSORS_HIH6130) += hih6130.o
|
||||
obj-$(CONFIG_SENSORS_HTU21) += htu21.o
|
||||
obj-$(CONFIG_SENSORS_ULTRA45) += ultra45_env.o
|
||||
obj-$(CONFIG_SENSORS_I5500) += i5500_temp.o
|
||||
obj-$(CONFIG_SENSORS_I5K_AMB) += i5k_amb.o
|
||||
|
|
|
@ -1,174 +0,0 @@
|
|||
/*
|
||||
* Measurement Specialties HTU21D humidity and temperature sensor driver
|
||||
*
|
||||
* Copyright (C) 2013 William Markezana <william.markezana@meas-spec.com>
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License as published by
|
||||
* the Free Software Foundation; either version 2 of the License, or
|
||||
* (at your option) any later version.
|
||||
*
|
||||
* This program is distributed in the hope that it will be useful,
|
||||
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||||
* GNU General Public License for more details.
|
||||
*
|
||||
*/
|
||||
|
||||
#include <linux/module.h>
|
||||
#include <linux/init.h>
|
||||
#include <linux/slab.h>
|
||||
#include <linux/i2c.h>
|
||||
#include <linux/hwmon.h>
|
||||
#include <linux/hwmon-sysfs.h>
|
||||
#include <linux/err.h>
|
||||
#include <linux/mutex.h>
|
||||
#include <linux/device.h>
|
||||
#include <linux/jiffies.h>
|
||||
|
||||
/* HTU21 Commands */
|
||||
#define HTU21_T_MEASUREMENT_HM 0xE3
|
||||
#define HTU21_RH_MEASUREMENT_HM 0xE5
|
||||
|
||||
struct htu21 {
|
||||
struct i2c_client *client;
|
||||
struct mutex lock;
|
||||
bool valid;
|
||||
unsigned long last_update;
|
||||
int temperature;
|
||||
int humidity;
|
||||
};
|
||||
|
||||
static inline int htu21_temp_ticks_to_millicelsius(int ticks)
|
||||
{
|
||||
ticks &= ~0x0003; /* clear status bits */
|
||||
/*
|
||||
* Formula T = -46.85 + 175.72 * ST / 2^16 from datasheet p14,
|
||||
* optimized for integer fixed point (3 digits) arithmetic
|
||||
*/
|
||||
return ((21965 * ticks) >> 13) - 46850;
|
||||
}
|
||||
|
||||
static inline int htu21_rh_ticks_to_per_cent_mille(int ticks)
|
||||
{
|
||||
ticks &= ~0x0003; /* clear status bits */
|
||||
/*
|
||||
* Formula RH = -6 + 125 * SRH / 2^16 from datasheet p14,
|
||||
* optimized for integer fixed point (3 digits) arithmetic
|
||||
*/
|
||||
return ((15625 * ticks) >> 13) - 6000;
|
||||
}
|
||||
|
||||
static int htu21_update_measurements(struct device *dev)
|
||||
{
|
||||
struct htu21 *htu21 = dev_get_drvdata(dev);
|
||||
struct i2c_client *client = htu21->client;
|
||||
int ret = 0;
|
||||
|
||||
mutex_lock(&htu21->lock);
|
||||
|
||||
if (time_after(jiffies, htu21->last_update + HZ / 2) ||
|
||||
!htu21->valid) {
|
||||
ret = i2c_smbus_read_word_swapped(client,
|
||||
HTU21_T_MEASUREMENT_HM);
|
||||
if (ret < 0)
|
||||
goto out;
|
||||
htu21->temperature = htu21_temp_ticks_to_millicelsius(ret);
|
||||
ret = i2c_smbus_read_word_swapped(client,
|
||||
HTU21_RH_MEASUREMENT_HM);
|
||||
if (ret < 0)
|
||||
goto out;
|
||||
htu21->humidity = htu21_rh_ticks_to_per_cent_mille(ret);
|
||||
htu21->last_update = jiffies;
|
||||
htu21->valid = true;
|
||||
}
|
||||
out:
|
||||
mutex_unlock(&htu21->lock);
|
||||
|
||||
return ret >= 0 ? 0 : ret;
|
||||
}
|
||||
|
||||
static ssize_t htu21_show_temperature(struct device *dev,
|
||||
struct device_attribute *attr, char *buf)
|
||||
{
|
||||
struct htu21 *htu21 = dev_get_drvdata(dev);
|
||||
int ret;
|
||||
|
||||
ret = htu21_update_measurements(dev);
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
return sprintf(buf, "%d\n", htu21->temperature);
|
||||
}
|
||||
|
||||
static ssize_t htu21_show_humidity(struct device *dev,
|
||||
struct device_attribute *attr, char *buf)
|
||||
{
|
||||
struct htu21 *htu21 = dev_get_drvdata(dev);
|
||||
int ret;
|
||||
|
||||
ret = htu21_update_measurements(dev);
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
return sprintf(buf, "%d\n", htu21->humidity);
|
||||
}
|
||||
|
||||
static SENSOR_DEVICE_ATTR(temp1_input, S_IRUGO,
|
||||
htu21_show_temperature, NULL, 0);
|
||||
static SENSOR_DEVICE_ATTR(humidity1_input, S_IRUGO,
|
||||
htu21_show_humidity, NULL, 0);
|
||||
|
||||
static struct attribute *htu21_attrs[] = {
|
||||
&sensor_dev_attr_temp1_input.dev_attr.attr,
|
||||
&sensor_dev_attr_humidity1_input.dev_attr.attr,
|
||||
NULL
|
||||
};
|
||||
|
||||
ATTRIBUTE_GROUPS(htu21);
|
||||
|
||||
static int htu21_probe(struct i2c_client *client,
|
||||
const struct i2c_device_id *id)
|
||||
{
|
||||
struct device *dev = &client->dev;
|
||||
struct htu21 *htu21;
|
||||
struct device *hwmon_dev;
|
||||
|
||||
if (!i2c_check_functionality(client->adapter,
|
||||
I2C_FUNC_SMBUS_READ_WORD_DATA)) {
|
||||
dev_err(&client->dev,
|
||||
"adapter does not support SMBus word transactions\n");
|
||||
return -ENODEV;
|
||||
}
|
||||
|
||||
htu21 = devm_kzalloc(dev, sizeof(*htu21), GFP_KERNEL);
|
||||
if (!htu21)
|
||||
return -ENOMEM;
|
||||
|
||||
htu21->client = client;
|
||||
mutex_init(&htu21->lock);
|
||||
|
||||
hwmon_dev = devm_hwmon_device_register_with_groups(dev, client->name,
|
||||
htu21,
|
||||
htu21_groups);
|
||||
return PTR_ERR_OR_ZERO(hwmon_dev);
|
||||
}
|
||||
|
||||
static const struct i2c_device_id htu21_id[] = {
|
||||
{ "htu21", 0 },
|
||||
{ }
|
||||
};
|
||||
MODULE_DEVICE_TABLE(i2c, htu21_id);
|
||||
|
||||
static struct i2c_driver htu21_driver = {
|
||||
.class = I2C_CLASS_HWMON,
|
||||
.driver = {
|
||||
.name = "htu21",
|
||||
},
|
||||
.probe = htu21_probe,
|
||||
.id_table = htu21_id,
|
||||
};
|
||||
|
||||
module_i2c_driver(htu21_driver);
|
||||
|
||||
MODULE_AUTHOR("William Markezana <william.markezana@meas-spec.com>");
|
||||
MODULE_DESCRIPTION("MEAS HTU21D humidity and temperature sensor driver");
|
||||
MODULE_LICENSE("GPL");
|
Loading…