[SPARC64]: Fix booting on V100 systems.
On the root PCI bus, the OBP device tree lists device 3 twice. Once as 'pm' and once as 'lomp'. Everything goes downhill from there. Ignore the second instance to workaround this. Thanks to Kövedi_Krisztián for the bug report and testing the fix. Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
577107e8e4
commit
2cc7345ff7
1 changed files with 12 additions and 1 deletions
|
@ -744,7 +744,7 @@ static void __devinit pci_of_scan_bus(struct pci_pbm_info *pbm,
|
|||
{
|
||||
struct device_node *child;
|
||||
const u32 *reg;
|
||||
int reglen, devfn;
|
||||
int reglen, devfn, prev_devfn;
|
||||
struct pci_dev *dev;
|
||||
|
||||
if (ofpci_verbose)
|
||||
|
@ -752,14 +752,25 @@ static void __devinit pci_of_scan_bus(struct pci_pbm_info *pbm,
|
|||
node->full_name, bus->number);
|
||||
|
||||
child = NULL;
|
||||
prev_devfn = -1;
|
||||
while ((child = of_get_next_child(node, child)) != NULL) {
|
||||
if (ofpci_verbose)
|
||||
printk(" * %s\n", child->full_name);
|
||||
reg = of_get_property(child, "reg", ®len);
|
||||
if (reg == NULL || reglen < 20)
|
||||
continue;
|
||||
|
||||
devfn = (reg[0] >> 8) & 0xff;
|
||||
|
||||
/* This is a workaround for some device trees
|
||||
* which list PCI devices twice. On the V100
|
||||
* for example, device number 3 is listed twice.
|
||||
* Once as "pm" and once again as "lomp".
|
||||
*/
|
||||
if (devfn == prev_devfn)
|
||||
continue;
|
||||
prev_devfn = devfn;
|
||||
|
||||
/* create a new pci_dev for this device */
|
||||
dev = of_create_pci_dev(pbm, child, bus, devfn, 0);
|
||||
if (!dev)
|
||||
|
|
Loading…
Reference in a new issue