ARM: S5PV210: use dma-pl330 device name for clock

This change replaces s3c-pl330.x clock device names with dma-pl330.x,
otherwise there won't be a correspondence between clock device name
and amba device name, thus clocks can't be enabled.

Fixes runtime errors on clk_get() from drivers/dma/pl330.c:
  dma-pl330 dma-pl330.0: Cannot get operation clock.
  dma-pl330: probe of dma-pl330.0 failed with error -22

Signed-off-by: Vladimir Zapolskiy <vz@mleia.com>
Acked-by: Boojin Kim <boojin.kim@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
This commit is contained in:
Vladimir Zapolskiy 2011-08-18 19:24:55 +09:00 committed by Kukjin Kim
parent d20cc4c1b6
commit 1ce3ea61c6

View file

@ -290,13 +290,13 @@ static struct clk_ops clk_fout_apll_ops = {
static struct clk init_clocks_off[] = {
{
.name = "pdma",
.devname = "s3c-pl330.0",
.devname = "dma-pl330.0",
.parent = &clk_hclk_psys.clk,
.enable = s5pv210_clk_ip0_ctrl,
.ctrlbit = (1 << 3),
}, {
.name = "pdma",
.devname = "s3c-pl330.1",
.devname = "dma-pl330.1",
.parent = &clk_hclk_psys.clk,
.enable = s5pv210_clk_ip0_ctrl,
.ctrlbit = (1 << 4),