regulator: ab8500: Remove get_voltage implementation for ab8500_regulator_fixed_ops

This is not required after commit f7df20ec
"regulator: core: Use list_voltage() to read single voltage regulators"

Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
Axel Lin 2012-08-10 09:34:53 +08:00 committed by Mark Brown
parent 88348effd6
commit 0d3fb582dc

View file

@ -257,16 +257,10 @@ static struct regulator_ops ab8500_regulator_ops = {
.set_voltage_time_sel = ab8500_regulator_set_voltage_time_sel, .set_voltage_time_sel = ab8500_regulator_set_voltage_time_sel,
}; };
static int ab8500_fixed_get_voltage(struct regulator_dev *rdev)
{
return rdev->desc->min_uV;
}
static struct regulator_ops ab8500_regulator_fixed_ops = { static struct regulator_ops ab8500_regulator_fixed_ops = {
.enable = ab8500_regulator_enable, .enable = ab8500_regulator_enable,
.disable = ab8500_regulator_disable, .disable = ab8500_regulator_disable,
.is_enabled = ab8500_regulator_is_enabled, .is_enabled = ab8500_regulator_is_enabled,
.get_voltage = ab8500_fixed_get_voltage,
.list_voltage = regulator_list_voltage_linear, .list_voltage = regulator_list_voltage_linear,
}; };